Publicaties
- pdf
Current state of the morphological assessment of urinary erythrocytes in The Netherlands: a nation- wide questionnaire
Luimstra JJ, Koçer RG, Jerman A, Klein Gunnewiek J, Gijzen K, Jacobs LHJ, Demir AY. Current state of the morphological assessment of urinary erythrocytes in The Netherlands: a nation-wide questionnaire. Clin Chem Lab Med. 2020 Oct 25;58(11):1891-1900. doi: 10.1515/cclm-2020-0236. PMID: 32335538. - pdf
Feasibility for aggregation of commutable external quality assessment results to evaluate metrological traceability and agreement among results
van der Hagen EAE, Weykamp C, Sandberg S, Stavelin AV, MacKenzie F, Miller WG. Feasibility for aggregation of commutable external quality assessment results to evaluate metrological traceability and agreement among results. Clin Chem Lab Med. 2020 Aug 6;59(1):117-125. doi: 10.1515/cclm-2020-0736. PMID: 32759402. - pdf
Big data and reference intervals: rationale, current practices, harmonization and standardization prerequisites and future perspectives of indirect determination of reference intervals using routine data
Martinez-Sanchez L, Marques-Garcia F, Ozarda Y, Blanco A, Brouwer N, Canalias F, Cobbaert C, Thelen M, den Elzen W. Big data and reference intervals: rationale, current practices, harmonization and standardization prerequisites and future perspectives of indirect determination of reference intervals using routine data. Adv Lab Med. 2020 Aug 8;2(1):9-25. doi: 10.1515/almed-2020-0034. PMID: 37359198; PMCID: PMC10197285. - pdf
First international external quality assessment scheme of nucleic acid amplification tests for the detection of Schistosoma and soiltransmitted helminths, including Strongyloides: A pilot study
Cools P, van Lieshout L, Koelewijn R, Addiss D, Ajjampur SSR, Ayana M, Bradbury RS, Cantera JL, Dana D, Fischer K, Imtiaz R, Kabagenyi J, Lok J, McCarthy J, Mejia R, Mekonnen Z, Njenga SM, Othman N, Shao H, Traub R, Van Esbroeck M, Vercruysse J, Vlaminck J, Williams SA, Verweij JJ, van Hellemond JJ, Levecke B. First international external quality assessment scheme of nucleic acid amplification tests for the detection of Schistosoma and soil-transmitted helminths, including Strongyloides: A pilot study. PLoS Negl Trop Dis. 2020 Jun 16;14(6):e0008231. doi: 10.1371/journal.pntd.0008231. PMID: 32544158; PMCID: PMC7319349. - pdf
First international external quality assessment scheme of nucleic acid amplification tests for the detection of Schistosoma and soil-transmitted helminths, including Strongyloides: A pilot studylity-assessment
Cools P, van Lieshout L, Koelewijn R, Addiss D, Ajjampur SSR, Ayana M, Bradbury RS, Cantera JL, Dana D, Fischer K, Imtiaz R, Kabagenyi J, Lok J, McCarthy J, Mejia R, Mekonnen Z, Njenga SM, Othman N, Shao H, Traub R, Van Esbroeck M, Vercruysse J, Vlaminck J, Williams SA, Verweij JJ, van Hellemond JJ, Levecke B. First international external quality assessment scheme of nucleic acid amplification tests for the detection of Schistosoma and soil-transmitted helminths, including Strongyloides: A pilot study. PLoS Negl Trop Dis. 2020 Jun 16;14(6):e0008231. doi: 10.1371/journal.pntd.0008231. PMID: 32544158; PMCID: PMC7319349. - pdf
External quality assessment schemes for inorganic elements in the clinical laboratory: Lessons from the OELM scheme
Arnaud J, Patriarca M, Fofou-Caillierez BM, González-Estecha M, Gómez MG, De Graaf I, Patriarca V, Ropert-Bouchet M, Schröer-Janssen L, Siebelder C, Te Winkel M, Ventura Alemany M, Weykamp C. External quality assessment schemes for inorganic elements in the clinical laboratory: Lessons from the OELM scheme. J Trace Elem Med Biol. 2020 May;59:126414. doi: 10.1016/j.jtemb.2019.126414. Epub 2019 Oct 11. PMID: 31810809. - pdf
Implementing Dried Blood Spot sampling in transplant patient care
Implementing Dried Blood Spot sampling in transplant patient care. Proefschrift. KKGT-sectielid Herman Veenhof, 24 februari 2020. - pdf
Hoe meten weten wordt
Rede uitgesproken bij de aanvaarding van het ambt van bijzonder hoogleraar Kwaliteit in de medische laboratoriumzorg aan de Radboud Universiteit/het Radbudumc op vrijdag 31 januari 2020 - door prof. dr. Marc H.M. Thelen - pdf
Fast 0/1-h algorithm for detection of NSTEMI: are current high-sensitivity cardiac troponin assays fit for purpose? An EQA-based evaluation
van der Hagen EAE, Cobbaert CM, Meijer R, Thelen MHM. Fast 0/1-h algorithm for detection of NSTEMI: are current high-sensitivity cardiac troponin assays fit for purpose? An EQA-based evaluation. Clin Chem Lab Med. 2019 Nov 26;57(12):1999-2007. doi: 10.1515/cclm-2019-0253. PMID: 31326959. - pdf
Commutability of proficiency testing material containing amitriptyline and nortriptyline: A study within the framework of the Dutch Calibration 2.000 project
Robijns K, Boone NW, Jansen RTP, Kuypers AWHM, Neef C, Touw DJ. Commutability of proficiency testing material containing amitriptyline and nortriptyline: A study within the framework of the Dutch Calibration 2.000 project. Clin Chim Acta. 2019 Nov;498:6-10. doi: 10.1016/j.cca.2019.07.036. Epub 2019 Jul 30. PMID: 31374190.
2020
2019